How to calculate degreasing cost per tonne of steel
Most quotations for steel degreasers are compared on price per kilogram. That number tells you almost nothing about what the cleaning stage costs. This guide shows how to build the only comparison that matters — cost per clean tonne — and where the money actually goes on a cold-rolling line.
1. Why price per kilogram points the wrong way
Two degreasers at the same price per kilogram can differ by 40% in cost per clean tonne. The difference hides in three places: the concentration needed to reach your cleaning specification, the bath life before the bath must be dumped, and the temperature the bath has to run at.
A product at 1.40 USD/kg that needs 6% make-up is more expensive than a product at 1.80 USD/kg that works at 4% — before you even look at heating. A bath that lasts six months instead of three halves chemical consumption. And a stage running at 60 °C spends roughly a third more on heating than the same stage at 45 °C.
Ask every supplier for three numbers in writing: make-up concentration to reach spec, expected bath life under your soil load, and the operating temperature window. Quotes without those three numbers cannot be compared.
2. The four components of degreasing cost
Build the comparison from four components. Only the first is visible on a quotation.
| Component | What drives it | Typical share on a CR line |
|---|---|---|
| Chemical consumption | Dose, bath volume, bath life, drag-out | 15–35% |
| Heating energy | Bath volume, operating temperature, insulation, standing losses | 30–55% |
| Rework and rejects | Residual oil, staining, flash rust, foam carryover | 10–30% |
| Downtime and labour | Bath dumps, cleaning cycles, manual touch-up | 5–15% |
The ranges are planning assumptions for alkaline cleaning of steel strip; the split depends on energy price, line speed and how disciplined bath management is. Measure your own before optimising.
3. Worked example (assumed inputs)
The numbers below are a model, not a client case. Substitute your own; the arithmetic is what matters.
Inputs: bath volume 20 m³, throughput 5,000 t/month, make-up concentration 4%, chemical price 1.60 USD/kg, bath life 3 months, operating temperature 60 °C, energy 0.12 USD/kWh.
| Step | Calculation | Result |
|---|---|---|
| Bath charge | 20 m³ × 4% × 1,000 kg/m³ = 800 kg per charge; 800 × 1.60 USD | 1,280 USD per charge |
| Chemical per month | 1,280 USD ÷ 3 months bath life | 427 USD/month |
| Chemical per tonne | 427 USD ÷ 5,000 t | 0.085 USD/t |
| Heat-up energy | 20 m³ × 60 K × 1.16 kWh/m³·K | 1,392 kWh per full heat-up |
| Monthly heating | 1,392 kWh × 15% daily standing loss × 30 days × 0.12 USD/kWh | ≈752 USD/month (0.150 USD/t) |
| Rework | 1.5% of 250 coils/month × 25 USD per re-clean ÷ 5,000 t | 0.019 USD/t |
| Total | Chemical + heating + rework | ≈0.254 USD/t |
Heating dominates. On this model, dropping the operating temperature from 60 °C to 45 °C cuts the heating line by roughly a quarter — about 0.037 USD/t, or 185 USD/month at this throughput. Removing heating entirely (a low-temperature system running at 10–15 °C) recovers about 0.11 USD/t.
4. Where the cost actually comes down
- Temperature first. Heating is the largest single line on most lines. A low-temperature alkaline system (5–15 °C) is the biggest lever where energy is expensive or winter operation makes heating impractical.
- Bath life second. Oil skimming, partial dumps and top-up discipline usually extend bath life more than switching products does.
- Dose third. Running 6% when the line cleans at 4% is pure waste. Run a concentration ladder during a trial rather than trusting the datasheet.
- Foam fourth. Foam carryover drags chemistry into the rinse stage, which then needs more rinse water and more anti-foam — a hidden cost that shows up as "the rinse does not work".
- Rework last. Residual oil and staining usually come from bath management, not from the product. Fix the bath before buying a stronger chemical.
5. Bath management checklist
| Item | Frequency | What good looks like |
|---|---|---|
| Concentration titration | Daily | Within ±10% of the trial set point |
| Oil skimming / separation | Continuous or daily | Free oil in the bath does not build up between dumps |
| Temperature check | Every shift | Stable within ±5 °C of set point |
| Rinse water conductivity | Daily | Stable; rising conductivity means carryover or poor rinsing |
| Partial dump schedule | Monthly | 10–20% of bath volume, based on oil load |
| Full bath dump | By bath life, not by calendar | Driven by oil saturation, not by habit |
6. Six defects and what they usually mean
| Defect | Likely cause | Countermeasure |
|---|---|---|
| Foam overflow | Over-dose, hard water, oil saturation, high spray pressure | Cut dose to trial value, skim oil, check water hardness, move to a low-foam grade |
| Residual oil film | Temperature too low, dose too low, contact time too short | Raise temperature 5–10 °C or dose 0.5%, extend contact time, increase skimming |
| Flash rust after rinse | Long transfer time, acidic rinse, high humidity | Shorten transfer, add rinse inhibitor, check rinse pH |
| Water spots / staining | Hard water salts, poor squeegee or drying, silicate residue | Soften final rinse, check squeegee pressure, request a non-silicate formulation |
| White residue on strip | Insufficient rinsing, over-dose, hard-water reaction | Add or increase a rinse stage, reduce dose, verify rinse quality |
| Short bath life | Heavy soil load, no skimming, wrong product for the soil | Maintain oil separation, consider a heavy-duty grade, schedule partial dumps |
7. Three-step trial protocol
A line trial should answer one question: at what concentration and temperature does this bath meet your cleaning specification, and how long does it last?
- Step 1 — ladder. Run three concentrations (for example 3%, 4%, 6%) at your current temperature for one shift each. Record the cleaning result and foam level for every coil.
- Step 2 — temperature. Take the lowest concentration that passed and drop the temperature in 5 °C steps until it fails. The last passing point is your operating floor, not your set point.
- Step 3 — bath life. Run at the chosen concentration and temperature for two full weeks without a dump, tracking titration and oil loading. If the bath drifts, you have found the real maintenance interval.
Change one variable per step. A trial that moves dose and temperature together produces a result nobody can reproduce.
Frequently asked questions
How much does steel degreaser cost per tonne of steel?
On cold-rolling lines, alkaline degreasing typically lands between 0.15 and 0.40 USD per tonne of steel when chemical and heating are both counted — with heating usually the larger share. The exact figure depends on bath volume, throughput, operating temperature and energy price, so it has to be modelled with your own inputs rather than quoted from a price list.
What temperature should an alkaline degreaser run at?
Most alkaline degreasers for cold-rolled steel are designed for 40–70 °C. Lower temperatures clean slower and may not remove thick rolling oil; higher temperatures speed cleaning but increase heating cost and evaporation. Low-temperature formulations exist that work from 5–15 °C, which is useful where energy is expensive or the plant runs unheated in winter.
Why does my degreasing bath foam?
Foaming is usually caused by over-dosing, oil saturation, hard water, or high spray pressure in a spray line. Check concentration against the trial value first, then oil skimming, then water hardness. Switching to a low-foam grade helps only after the dose and oil load are under control.
How often should a degreasing bath be dumped?
Base it on oil saturation rather than the calendar: track oil loading and titration drift, and schedule partial dumps monthly and a full dump when the bath can no longer hold the cleaning result. Baths dumped on a fixed calendar schedule are often dumped too early or too late.
Is a low-temperature degreaser as effective as a hot bath?
It depends on the soil. A low-temperature alkaline system can clean typical rolling oils at 10–15 °C, but very heavy or pigmented soils may still need heat or a heavier-duty grade. The only reliable answer is a temperature-ladder trial on your own coils.
What information do I need before requesting a quotation?
Substrate and line type, bath volume and operating temperature, contact time and rinse configuration, the oil or soil being removed, water hardness, monthly tonnage and any restriction such as silicate-free or low-foam. With those, a supplier can propose a starting concentration and a trial plan instead of guessing.
Get the technical pack and a cost model for your line
Send your bath volume, throughput, temperature and energy price. We will return a one-page cost comparison between BT-680, BG-835, BG-850 and SUPER-350 on your numbers, plus TDS and a trial protocol. No sales call unless you ask for one.
Figures in this guide are planning assumptions and general process guidance, not a performance warranty. Confirm concentrations, temperatures and maintenance intervals in a line trial and against the product TDS.